Lost Power to Part of the House? Causes and Next Steps
When only part of the house loses power, the cause is usually a tripped breaker, a tripped GFCI outlet upstream, a failed wire connection in a box, or a problem on the utility's side such as a lost leg or a loose neutral. The first two you can check yourself. The others need the utility, a licensed electrician, or both.
Safety first: If you see smoke, fire, or sparking that will not stop, get everyone out and call 911. Do not open the panel or touch damaged equipment.
What does it mean when only part of the house has power?
Most homes get a 120/240-volt, three-wire service. Two "hot" legs and a neutral come from the utility transformer. Each 120-volt circuit is fed from one leg. Larger loads, like an electric dryer or electric range, use both legs for 240 volts. So when one leg, one breaker, or one connection fails, you lose some circuits and keep others.
Quick guide: symptom, likely cause, who to call
| What you see | Likely cause | Who to call |
|---|---|---|
| One room or area dead, a breaker sits in the middle or OFF position | Tripped breaker | Reset once. If it trips again, call an electrician. |
| Some outlets dead in a bathroom, kitchen, garage, basement or outside | Tripped GFCI outlet upstream | Press RESET on the GFCI. If it will not reset, call an electrician. |
| About half the house dead, electric dryer or range will not heat or run, no tripped breakers | Lost leg (one hot leg not reaching the house) | Your electric utility first, such as PSE&G. |
| Lights brighter in some rooms and dimmer in others, or lights change when big appliances start | Loose or open neutral | The utility and an electrician, right away |
| One string of outlets dead, no breaker tripped, a warm or discolored outlet, a burning smell | Failed connection in a box | An electrician |
Is it a tripped breaker?
Open the panel door and look for a breaker that is in the middle or the OFF position. Push it fully to OFF, then back to ON. If it trips again, leave it off. NFPA lists frequent breaker trips as a reason to call a qualified electrician. Repeated trips can mean an overload, a damaged cord or appliance, or a wiring fault.
Could a GFCI outlet be the problem?
Yes, this is common when "some outlets are not working." A GFCI receptacle protects itself and other outlets further "down stream" on the same circuit, according to the CPSC. So a tripped GFCI in a bathroom or garage can cut power to outlets in another room. Look for GFCI outlets in bathrooms, kitchens, garages, basements and outdoors, and press RESET. The CPSC also says to test GFCIs after a power failure. If a GFCI will not reset, or its test button does not cut the power, it needs an electrician. See our GFCI and AFCI requirements page.
What is a lost leg, and why do 240-volt appliances stop?
If one of the two hot legs is not reaching the house, every 120-volt circuit on that leg goes dark. Anything that needs 240 volts, like an electric dryer or electric range, will not work right because it needs both legs. Breakers will look normal. This is often a problem with the utility's wire or connection, but it can also be a burned connection in the meter pan or main breaker.
Check whether neighbors have the same problem. Then report it to the utility and say you have "partial power." For PSE&G customers:
- Text OUT to 4PSEG (47734)
- Call 1-800-436-PSEG (7734)
- Use the PSE&G app or report online at nj.pseg.com
If the utility finds its side is fine, the problem is on your side of the connection and needs a licensed electrician.
What are the danger signs of a loose neutral?
A loose or open neutral is the most serious cause on this page. When the neutral opens, the voltage on one leg rises and the other drops. Signs include:
- Lights very bright in some rooms and dim in others
- Lights changing when the dryer, AC or microwave starts
- Electronics or bulbs failing in a short time
- A tingle when you touch an appliance or a metal fixture
Trade sources warn that voltages far from normal create a fire hazard, and that metal parts and piping can become energized. Utilities advise turning off the main breaker if it is safe to reach and calling them. Then have an electrician check your service neutral and grounding and bonding.
Could it be a failed connection in a box?
Yes. Outlets and lights on one circuit are wired through each other. If a wire comes loose or burns at one outlet, switch or splice, everything past that point goes dead while the breaker stays on. Warning signs from NFPA include warm or discolored outlets, flickering or dimming lights, sparks from an outlet, and a burning or rubbery smell. Stop using that circuit and call an electrician. Do not open boxes yourself.
Utility or electrician: who fixes what?
PSE&G says it is responsible for the service wire from the pole to the point of connection on your home, and for replacing damaged meters. The homeowner is responsible for the service wire hook, weatherhead, entrance cable or pipe, and meter pan, plus tripped breakers and dead outlets inside. PSE&G says a licensed electrician must repair the customer-owned parts before it can permanently restore service. If a storm pulled the service off the house, see our storm damage page.
NJ permit and inspection note
Repairs to wiring, panels and service equipment in New Jersey need a permit and a licensed electrician, and the local inspector has the final say. New Jersey adopted the 2023 National Electrical Code under N.J.A.C. 5:23-3.16 as of August 17, 2026. Complete permit applications submitted through February 17, 2027 may still be reviewed under the prior code (NEC 2020). Learn more in our NJ electrical code library.
How Gareffa Electric can help
Gareffa Electric is a family-owned, licensed New Jersey electrical contractor (NJ Electrical Contractor License #18578), based in Nutley and serving Bergen, Hudson, Essex and Passaic counties. We carry $2M in liability insurance, and a bond is available on request. Every job is permitted in our name and done by licensed electricians on our crew.
- We trace dead circuits, failed connections, breakers and GFCIs. See electrical repair in NJ.
- We repair customer-owned service equipment so the utility can restore power. See power outage electrician.
- If the panel itself is the problem, we replace old Federal Pacific and Zinsco panels and do 200A panel upgrades. See Federal Pacific panel replacement.
Same-day or next-day dispatch is available, and we are often there within 2 to 4 hours of booking. Book a $150 scheduled service call (includes diagnostic and the first hour; the fee is credited on jobs over $1,500) or a $350 same-day service call. We are not a 24/7 service. Outside our hours, report utility problems to PSE&G and call 911 for fire or immediate danger.
Frequently asked questions
Why did half my house lose power when no breakers are tripped?
The most likely cause is a lost leg, where one of the two hot legs is not reaching the house. Report "partial power" to your utility. If its side checks out, an electrician should check the meter pan, service entrance and main breaker.
Why are some outlets not working while the lights still work?
Look for a tripped GFCI outlet upstream and press RESET. If nothing resets, a loose or burned connection in an outlet box is likely, and an electrician should find it.
Are lights that get brighter and dimmer dangerous?
Yes. It is a sign of a loose or open neutral, which can damage equipment and create a fire hazard. If it is safe, turn off the main breaker, call the utility, and have an electrician check the service.
Should I call PSE&G or an electrician first?
Call the utility when about half the house is out, 240-volt appliances fail, or lights are dim and bright. Call an electrician for tripped breakers that will not hold, GFCIs that will not reset, warm outlets, or one dead circuit.
Who is responsible for the meter pan or the pipe on the side of my house?
PSE&G says the homeowner is responsible for the service wire hook, weatherhead, entrance cable or pipe, and meter pan, and must use a licensed electrician to repair them. Those repairs must be made before PSE&G can permanently restore service.
Can you come at night or on Sunday?
No. We work Monday to Saturday, 7 AM to 6 PM, and are closed Sunday. For utility problems after hours, contact PSE&G. For smoke, fire or sparking, call 911.
Call Gareffa Electric at (973) 662-4333, Monday to Saturday, 7 AM to 6 PM (closed Sunday).