Why Does My Breaker Keep Tripping?
A breaker that keeps tripping is usually doing its job. It is cutting power because the circuit is overloaded, has a short circuit, has a ground fault, or has an arc fault. The pattern of when it trips tells you which one it most likely is.
If you see smoke, fire, or sparking that will not stop, leave the building and call 911. Do not go back to the panel.
What does a breaker actually protect?
A breaker protects the wire in your walls. It opens when current climbs high enough to overheat the wire. It also reacts to short circuits and ground faults. Some breakers and outlets add extra protection:
- AFCI (arc-fault) devices have electronics that sense dangerous arcing and shut off power before a fire can start.
- GFCI (ground-fault) devices protect people from serious shocks. They trip when current leaks out of the circuit along a path it should not take.
For where NJ code calls for each one, see our GFCI and AFCI requirements guide.
Overload, short circuit, ground fault or arc fault: what is the difference?
- Overload: Too many things are running on one circuit. A common example is a space heater, hair dryer or microwave sharing a circuit with other loads.
- Short circuit: A hot wire touches a neutral or another hot wire. Current jumps very high, very fast.
- Ground fault: A hot wire touches ground, a metal box, or water. Wet outdoor outlets, bathrooms and basements are common spots.
- Arc fault: Current jumps across damaged, loose or stressed wiring. Arcing can come from cracked old insulation, a nail or screw through a wire behind a wall, or a loose connection.
How can I tell which one it is?
Watch when it trips. This table is a starting point, not a diagnosis.
| When it trips | Most likely cause | What it usually means |
|---|---|---|
| After several minutes with many things running | Overload | Too much load on one circuit |
| Only when one appliance turns on | Faulty appliance or overload | Test without that appliance |
| The instant you reset it, with everything unplugged | Short circuit or ground fault | Likely a wiring or device fault |
| GFCI trips after rain or in a damp area | Ground fault | Moisture in an outlet, box or fixture |
| AFCI trips at random, or when a cord is moved | Arc fault | Damaged cord, loose connection or wiring problem |
| Trips with almost nothing on, or will not stay set | Worn breaker or wiring fault | Needs a licensed electrician |
What is safe to do when a breaker trips?
- Turn off and unplug everything on that circuit.
- Look for warning signs: burning smell, scorch marks, warm outlets or switch plates, buzzing. If you find any, stop and call an electrician.
- Reset the breaker once. Push it fully to OFF, then back to ON.
- If it holds, plug things back in one at a time. If it trips when one item goes on, stop using that item.
- If it trips again right away with nothing plugged in, leave it off. Do not keep resetting it.
The U.S. Consumer Product Safety Commission advises finding out why a breaker trips, instead of just resetting it. Do not open the panel or replace parts yourself. Electrical work in NJ needs a permit and a licensed electrician.
Can I just put in a bigger breaker?
No. Never upsize a breaker to stop it from tripping. The breaker is sized to the wire, not to the load. The National Electrical Code limits common copper branch circuits to 15 amps on 14 AWG, 20 amps on 12 AWG, and 30 amps on 10 AWG, with limited exceptions. A bigger breaker on the same wire lets the wire overheat before anything shuts off. That is a fire risk. Read more in our breaker sizing guide. The real fix for a true overload is often a new circuit, or a panel upgrade when the panel is full.
When does tripping mean a wiring fault?
Suspect the wiring when:
- It trips instantly with everything unplugged.
- An AFCI keeps tripping after you remove the suspect appliance. Shared neutrals, a neutral touching ground, or a wire pinched by a staple can all cause this.
- You smell burning or see heat damage at an outlet, switch or the panel.
- It started after renovation work, a picture hanging, or water getting into a wall.
These need testing by a licensed electrician. Our electrical repair service covers outlets, switches, GFCIs and breakers.
Could my older panel be the problem?
Sometimes. A worn breaker can trip when it should not, or fail to trip when it should. Federal Pacific Electric (FPE) Stab-Lok breakers get extra attention. The CPSC found that some failed calibration tests. It closed its investigation in 1983 without deciding whether they pose a serious risk. In 2011 its staff added a note stressing that the agency made no ruling either way on their safety. If your home has an FPE or Zinsco panel, have it looked at. See our Federal Pacific panel replacement page.
NJ permit and inspection note
New Jersey adopted the 2023 National Electrical Code under N.J.A.C. 5:23-3.16 as of August 17, 2026. Complete permit applications submitted through February 17, 2027 may still be reviewed under the 2020 NEC. New circuits, breaker and panel work need a permit and inspection. The local inspector has the final say. See our NJ electrical code library.
When should I call an electrician?
- It trips again right after one reset.
- It trips with nothing plugged in.
- You see scorch marks, smell burning, or feel heat.
- The breaker will not reset or feels loose.
- You have an FPE or Zinsco panel.
- One circuit trips often and you need more capacity.
How Gareffa Electric can help
Gareffa Electric is a family-owned, licensed NJ electrical contractor (NJ Electrical Contractor License #18578). We carry $2M in liability insurance, and a bond is available on request. We are based in Nutley and serve Bergen, Hudson, Essex and Passaic counties.
- We find the cause: overload, bad device, wiring fault or a failing breaker.
- We repair outlets, switches, GFCIs and breakers, and add circuits where load is the problem.
- We do panel and service upgrades, sub panels, and old Federal Pacific and Zinsco panel replacements.
- Every job is permitted in our name and done by licensed electricians on our crew.
Book a $150 scheduled service call (includes diagnostic and the first hour; the fee is credited on jobs over $1,500) or a $350 same-day service call. For planned work, book a free estimate visit. Same-day or next-day dispatch is available, and we are often there within 2 to 4 hours of booking. Want a broader look? Ask about a home electrical safety check.
FAQ
Why does my breaker trip immediately when I reset it?
If it trips the instant you reset it with everything unplugged, it is most likely a short circuit or ground fault in the wiring or a device. Leave it off and call a licensed electrician.
How many times can I reset a tripped breaker?
Reset it once after unplugging everything on the circuit. If it trips again, stop. Repeated resets can make a wiring fault worse.
Can I replace a 15-amp breaker with a 20-amp breaker?
Not to stop tripping. Breaker size is set by the wire, such as 15 amps for 14 AWG copper. A larger breaker on smaller wire is a fire risk. Whether a circuit can be 20 amps depends on the wire and the outlets. A licensed electrician has to check that, and the work needs a permit.
Why does my AFCI breaker keep tripping?
It may be sensing real arcing from a damaged cord, loose connection or wire damage. Shared neutrals or a neutral touching ground can also cause trips. Remove the suspect appliance first; if it still trips, have the circuit tested.
Why does my GFCI trip when it rains?
Moisture in an outdoor outlet, box or fixture can let current leak to ground. The GFCI is cutting power to protect people from shock. Have the wet location checked and sealed.
Can a breaker go bad?
Yes. A worn breaker can trip at normal loads or fail to trip when it should. Older panels, including Federal Pacific, deserve a closer look.
Do you offer 24/7 emergency service?
No. We work Monday to Saturday, 7 AM to 6 PM. If there is smoke, fire or sparking that will not stop, leave and call 911.
Call Gareffa Electric at (973) 662-4333. Monday to Saturday, 7 AM to 6 PM. Closed Sunday.